Hoge kwaliteit IEC/BS/ASTM standaard abc antenne gebundeld kabel

Hoge kwaliteit IEC/BS/ASTM standaard abc antenne gebundeld kabel
Haven: Qingdao or Shanghai Any port in China
Betalingsvoorwaarden: L/C,D/A,D/P,T/T,Western Union
Leveringscapaciteit: 300 Kilometer/kilometers per Month
plaats van herkomst: Henan china
naam van het merk: JinShui
modelnummer: ABC KABEL
isolatiemateriaal: PVC
type: Hoogspanning
toepassing: Overhead
leidingmateriaal: Aluminium
Certificaat: ISO, CE, BV, ROHS
Dirigent Type: Gestrand
Type: Geïsoleerde
Details verpakking: Hoge kwaliteit IEC/BS/ASTM standaard abc antenne gebundeld kabel is verpakt met houten of ijzeren drum of als klant eis.

 

        High quality IEC/BS/ASTM standard abc aerial bundled cable  is applied to overhead power line with rated voltage 0.6/1kv and 10KV. 

        High quality IEC/BS/ASTM standard abc aerial bundled cable  is mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.

 

    1kv abc cable, 11kv abc cable, 33kv abc cable

 

1 .Type:Duplex Service Drop, Triplex Service Drop, Quadruplex Service Drop

     

    a Duplex Service Drop

   Applications:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.

 

   b Triplex Service Drop

   Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .

 

    c Quadruplex Service Drop

    Applications: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

 

 

2 . Construction

        
     a Phase Conductor construction:The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.

 

    b  Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:

Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded

Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded

Aluminum alloy 6201-T81, concentric-lay-stranded

 

    c Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)

Alternatively, black linear low-density polyethylene (LLDPE) insulation with a 75°C temperature rating is available upon request. 

 

 3. specification

    

Code Name

Phase Conductor

Bare Neutral Messenger

Weight Per 1000ft (lbs)

Ampacity(amps)

Size AWG

Stranding

Insulation Thickness(mls)

Size AWG

Stranding

Breaking Strength(lbs)

XLPE

Poly

XLPE

Poly

6201 ALLOY NEUTRAL-MESSENGER

Minex

6

Solid

45

6

7

1,110

106.6

102.9

85

70

Hippa

6

7

45

6

7

1,110

113.2

105.7

85

70

Prawn

4

Solid

45

4

7

1,760

158.4

154.1

115

90

Barnacles

4

7

45

4

7

1,760

168.3

158.2

115

90

Shrimp

2

7

45

2

7

2,800

253.7

239.7

150

120

Gammarus

1/0

7

60

1/0

7

4,460

411.7

386.0

205

160

Leda

1/0

19

60

1/0

7

4,460

402.7

386.0

205

160

Dungenese

2/0

7

60

2/0

7

5,390

506.8

476.3

235

185

Cyclops

2/0

19

60

2/0

7

5,390

495.3

476.3

235

185

Dlustra

3/0

19

60

3/0

7

6,790

611.4

589.1

275

215

Lepas

4/0

19

60

4/0

7

8,560

757.1

730.5

315

245

 

 

4. Standards

1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

 

 

 

 

 

 

Tags: , ,

Contact us

 

 

 

zoeken