Controle straatverlichting ABC kabel driefasige vier draad installatie voor AC laagspanning schakelaar boord lijn
Haven: | Qingdao, Shanghai, Ningbo, Tianjin, Guangzhou, Dalian, Shenzhen, Yingkou |
Betalingsvoorwaarden: | L/C,D/P,T/T,Western Union,MoneyGram,Paypal payment also accept of the aaac bare conductor |
Leveringscapaciteit: | 2500 Kilometer/kilometers per Month de hoeveelheid afhankelijk abc kabel grootte. |
plaats van herkomst: | Henan china |
naam van het merk: | Hongda |
modelnummer: | ACSR |
isolatiemateriaal: | PVC |
type: | Laagspanning |
toepassing: | Overhead |
leidingmateriaal: | Aluminium |
jas: | Geen schede |
Nominale Spanning: | 0.6/1kV |
Toepassing: | Industriële en overhead |
Gestrand: | IEC, DIN, ASTM, BS, UL Standaard |
Isolatie: | PE/PVC/XLPE |
Core: | Multi-core abc kabel |
Certificaat: | ISO9001/CCC |
Verpakking: | Houten Trommel |
Dirigent Materiaal: | Aluminium/Aluminium/Aluminium bekleed staal |
Armour: | Staaldraad Armour |
Dirigent Type: | 2 gestrand aaac blote geleider |
Details verpakking: | abc kabel voor export houten drum, houten ijzer drum of andere export standaard pakket. We kunnen ook verpakken volgens uw vereiste. |
Controle straatverlichting ABC kabel drie-fase vier draad installatie voor AC laagspanning schakelaar board lijn
1. toepassingen
AAC dirigent:
- Rails op H.V. Onderstations
- L.V. distributie lijnenAaac blote geleider
- Geleiders voor geïsoleerde kabels (verdicht)
- Overhead transmissie en distributie lijnen medium, hoge en extra hoge spanning.
- H.V. Overhead transmissie en distr bution lijnen.
- Speciaal aanbevolen in corrosieve omgevingen, crossings, of waar een zeer hoge Treksterkte (UTS) nodig is.
- H.V. Overhead transmissie en distributie lijnen
- Speciaal aanbevolen in, crossings, of waar een zeer hoge treksterkte nodig is.
- Overhead transmissie lijnen medium, hoge en extra hoge spanning
- H.V. Overhead transmissie en distributie lijnen.
- Bus bars in H.V. Onderstations.
- Rails op H.V. Onderstations.
- H.V. overhead lijnen.
2. producten bereik
1) AAAC dirigent (Alle Aluminium Geleiders)
2) ACSR dirigent (Aluminium Geleider Staal Versterkte)
3) AAC dirigent (Alle Aluminium Geleiders)Aaac blote geleider
4) AACSR dirigent (Aluminium Geleiders Staal Versterkte)
5) ACSR/AW dirigent (Aluminium Geleider Aluminium Beklede Staal Versterkte)
AAAC, AAC, ACSR, AACSR, ACSR/AW acsr Geleiders geproduceerd volledig in overeenstemming met internationale standaard zoals IEC, BS, ASTM, DIN, JIS, NF, CSA, AS/NZS.
Aaac blote geleider
3. elatieve productie normen: IEC83, IEC1089, 31, B232, BS215, DIN48204.
Alle Aluminium Geleider (AAC) & Aluminium Dirigent Staal Versterkte (ACSR)) voor ASTM
(AAC, ACCR, AAAC, ACSR) Algemeen Bevestigt aan IS 398 (Deel-I, II, IV), IEC-228
(AAAC) Dirigent als per ASTM-B-399-1992
(AAAC) Dirigent als per BS-3242-1970
(AAAC) Dirigent IS: 398-IV-1994
(ACSR) als per ASTM-B-233-1992
(AAC) als per BS-215-1-1970Aaac blote geleider
(AAC) als per IS-398-1: 1976
(AAC) als per ASTM-B-231-1990
(ACSR) als per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970Aaac blote geleider
(AACSR) als per IEC-1089-1191
AAC (Alle aluminium geleider) zijn geschikt voor overhead power line.
Wij kunnen dit dirigent volgens verschillende erkende normen, zoals IEC61089, BS215, NEN-EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, klant speciale specificatie ook kan worden voldaan.
Toepassingen:
Gebruikt als kale overhead transmissie kabel en als primaire en secundaire distributie kabel. ACSR biedt optimale sterkte voor lijn ontwerp. Variabele stalen kern stranding maakt gewenste sterkte worden bereikt zonder in te boeten ampacity.Aaac blote geleider
Aaac blote geleider
4. specificaties:
ACSR blote geleider voldoet aan of overtreft de volgende ASTM specificaties:
B-230 Aluminium Draad, 1350-H19 voor Elektrische Doeleinden
B-231 Aluminium Geleiders, Concentrische-Lay-GestrandAaac blote geleider
B-232 Aluminium Geleiders, Concentrische-Lay-Gestrand, Gecoat Staal Versterkte (ACSR)
B-341 Aluminium bekleed Staal Core Draad voor Aluminium Geleiders, Staal Versterkte (ACSR/AW)
B-498 Verzinkt Stalen Kern Draad voor Aluminium Geleiders, Staal Versterkte (ACSR/AZ)
B-500 Verzinkt en Aluminium Gecoat Stranded Steel Core voor Aluminium Geleiders, Staal Versterkte (ACSR)
Gebied | Stranding en draad Diameter | Totale Diameter | ||||
Norminal | Werkelijke | |||||
Alu/staal Mm2 |
Alu Mm2 |
Staal Mm2 |
Totaal Mm2 |
Aluminium Mm |
Staal Mm |
Mm |
16/2. 5 | 15.3 | 2.5 | 17.8 | 6/1. 80 | 1/1. 80 | 5.4 |
25/4. 0 | 23.8 | 4.0 | 27.8 | 6/2. 25 | 1/2. 25 | 6.8 |
35/6. 0 | 34.3 | 5.7 | 40.0 | 6/2. 70 | 1/2. 70 | 8.1 |
44/32. 0 | 44.0 | 31.7 | 75. | 14/2. 00 | 7/2. 40 | 11.2 |
50/8. 0 | 48.3 | 8.0 | 56.3 | 6/3. 20 | 1/3. 20 | 9.6 |
50/30 | 51.2 | 29.8 | 81.0 | 12/2. 33 | 7/2. 33 | 11.7 |
70/12 | 69.9 | 11.4 | 81.3 | 26/1. 85 | 7/1. 44 | 11.7 |
95/15 | 94.4 | 15.3 | 109.7 | 26/2. 15 | 7/1. 67 | 13.6 |
95/55 | 96.5 | 56.3 | 152.8 | 12/3. 20 | 7/3. 20 | 16.0 |
105/75 | 105.7 | 75.5 | 181.5 | 14/3. 10 | 19/2. 25 | 17.5 |
120/20 | 121.6 | 19.8 | 141.4 | 26/2. 44 | 7/1. 90 | 15.5 |
125/30 | 127.9 | 29.8 | 157.7 | 30/2. 33 | 7/2. 33 | 16.3 |
120/70 | 122.0 | 71.3 | 193.3 | 12/3. 60 | 7/3. 60 | 18 |
150/25 | 148.9 | 24.2 | 173.1 | 26/2. 70 | 7/2. 10 | 17.1 |
170/40 | 171.8 | 40.1 | 211.9 | 30/2. 70 | 7/2. 70 | 18.9 |
185/30 | 183.8 | 29.8 | 213.6 | 26/3. 00 | 7/2. 33 | 19.0 |
210/35 | 209.1 | 34.1 | 243.2 | 26/3. 20 | 7/2. 49 | 20.3 |
210/50 | 212.1 | 49.5 | 261.6 | 30/3. 00 | 7/3. 00 | 21.0 |
230/30 | 230.9 | 29.8 | 260.7 | 24/3. 50 | 7/2. 33 | 21.0 |
240/40 | 243.0 | 39.5 | 282.5 | 26/3. 45 | 7/2. 68 | 21.9 |
265/35 | 263.7 | 34.1 | 297.8 | 24/3. 74 | 7/2. 49 | 22.4 |
300/50 | 304.3 | 49.5 | 353.7 | 26/3. 86 | 7/3. 00 | 24.5 |
Aaac blote geleider
ABC Kabel Met AAAC Messenger Core
Spec. Mm2 |
Dirigent structuur | Isolatie Materiaal | Isolatie Dikte (mm) | Verpakking Meter per Drum | |
Fase (Verdicht AL) | Neutrale (Legering) | ||||
(No./mm) |
Aluminium (No./mm) |
||||
1×16 + 1×16 | 7/1. 72 | 7/1. 72 | XLPE (HDPE) | 1.2 | 250-4000 m |
1×25 + 1×25 | 7/2. 15 | 7/2. 15 | 1.2 | 250-4000 m | |
1×35 + 1×35 | 7/2. 54 | 7/2. 54 | 1.4 | 250-3500 m | |
1×50 + 1×50 | 7/2. 92 | 7/2. 92 | 1.4 | 250-3000 m | |
1×70 + 1×70 | 19/2. 15 | 19/2. 15 | 1.4 | 250-3000 m | |
1×95 + 1×95 | 19/2. 54 | 19/2. 54 | 1.6 | 250-3000 m | |
2×16 + 1×16 | 7/1. 72 | 7/1. 72 | 1.2 | 250-4000 m | |
2×25 + 1×25 | 7/2. 15 | 7/2. 15 | 1.2 | 250-3500 m | |
2×35 + 1×35 | 7/2. 54 | 7/2. 54 | 1.4 | 250-3500 m | |
2×50 + 1×50 | 7/. 292 | 7/2. 92 | 1.4 | 250-3000 m | |
2×70 + 1×70 | 19/2. 15 | 19/2. 15 | 1.4 | 250-3000 m | |
2×95 + 1×95 | 19/2. 54 | 19/2. 54 | 1.6 | 250-3000 m | |
3×16 + 1×16 | 7/1. 72 | 7/1. 72 | 1.2 | 250-3500 m | |
3×25 + 1×25 | 7/2. 15 | 7/2. 15 | 1.2 | 250-3500 m | |
3×35 + 1×35 | 7/2. 54 | 7/2. 54 | 1.4 | 250-3000 m | |
3×50 + 1×50 | 7/2. 92 | 7/2. 92 | 1.4 | 250-3000 m | |
3×70 + 1×70 | 19/2. 15 | 19/2. 15 | 1.4 | 250-3000 m | |
3×95 + 1×95 | 19/2. 54 | 19/2. 54 | 1.6 | 250-3000 m |
ABC Kabel Zonder Messenger Core
Spec. Mm2 |
Dirigent structuur | Isolatie Materiaal | Isolatie Dikte (mm) | Verpakking Meter per Drum |
Verdicht Aluminium (No./mm) |
||||
2×16 | 7/1. 72 | XLPE (HDPE) | 1.2 | 250-4000 m |
2×25 | 7/2. 15 | 1.2 | 250-4000 m | |
2×35 | 7/2. 54 | 1.4 | 250-3500 m | |
2×50 | 7/2. 92 | 1.4 | 250-3000 m | |
2×70 | 19/2. 15 | 1.4 | 250-3000 m | |
2×95 | 19/2. 54 | 1.6 | 250-3000 m | |
3×16 | 7/1. 72 | 1.2 | 250-4000 m | |
3×25 | 7/2. 15 | 1.2 | 250-3500 m | |
3×35 | 7/2. 54 | 1.4 | 250-3500 m | |
3×50 | 7/. 292 | 1.4 | 250-3000 m | |
3×70 | 19/2. 15 | 1.4 | 250-3000 m | |
3×95 | 19/2. 54 | 1.6 | 250-3000 m | |
4×16 | 7/1. 72 | 1.2 | 250-3500 m | |
4×25 | 7/2. 15 | 1.2 | 250-3500 m | |
4×35 | 7/2. 54 | 1.4 | 250-3000 m | |
4×50 | 7/2. 92 | 1.4 | 250-3000 m | |
4×70 | 19/2. 15 | 1.4 | 250-3000 m | |
4×95 | 19/2. 54 | 1.6 | 250-3000 m |
ABC Kabel Met ACSR Messenger Core
Spec. Mm2 |
Dirigent structuur | Isolatie Materiaal | Isolatie Dikte (mm) | Verpakking Meter per Drum | ||
Fase (Verdicht AL) | Neutrale (Kale ACSR) | |||||
(No./mm) |
Aluminium (No./mm) |
Staal (No./mm) |
||||
1×16 + 1×16 | 7/1. 72 | 6/1. 72 | 1/1. 72 | XLPE (HDPE) | 1.2 | 250-4000 m |
1×25 + 1×25 | 7/2. 15 | 6/2. 15 | 1/2. 15 | 1.2 | 250-4000 m | |
1×35 + 1×35 | 7/2. 54 | 6/2. 54 | 1/2. 54 | 1.4 | 250-3500 m | |
1×50 + 1×50 | 7/2. 92 | 6/2. 92 | 1/2. 92 | 1.4 | 250-3000 m | |
1×70 + 1×70 | 19/2. 15 | 12/2. 15 | 7/2. 15 | 1.4 | 250-3000 m | |
1×95 + 1×95 | 19/2. 54 | 12/2. 54 | 7/2. 54 | 1.6 | 250-3000 m | |
2×16 + 1×16 | 7/1. 72 | 6/1. 72 | 1/1. 72 | 1.2 | 250-4000 m | |
2×25 + 1×25 | 7/2. 15 | 6/2. 15 | 1/2. 15 | 1.2 | 250-3500 m | |
2×35 + 1×35 | 7/2. 54 | 6/2. 54 | 1/2. 54 | 1.4 | 250-3500 m | |
2×50 + 1×50 | 7/. 292 | 6/2. 92 | 1/2. 92 | 1.4 | 250-3000 m | |
2×70 + 1×70 | 19/2. 15 | 12/2. 15 | 7/2. 15 | 1.4 | 250-3000 m | |
2×95 + 1×95 | 19/2. 54 | 12/2. 54 | 7/2. 54 | 1.6 | 250-3000 m | |
3×16 + 1×16 | 7/1. 72 | 6/1. 72 | 1/1. 72 | 1.2 | 250-3500 m | |
3×25 + 1×25 | 7/2. 15 | 6/2. 15 | 1/2. 15 | 1.2 | 250-3500 m | |
3×35 + 1×35 | 7/2. 54 | 6/2. 54 | 1/2. 54 | 1.4 | 250-3000 m | |
3×50 + 1×50 | 7/2. 92 | 6/2. 92 | 1/2. 92 | 1.4 | 250-3000 m | |
3×70 + 1×70 | 19/2. 15 | 12/2. 15 | 7/2. 15 | 1.4 | 250-3000 m | |
3×95 + 1×95 | 19/2. 54 | 12/2. 54 | 7/2. 54 | 1.6 | 250-3000 m |
Opmerkingen:
Weerstand is berekend met ASTM standaard stappen van stranding en metalen geleidbaarheid van 61.2% IACS voor EC (1350) en 8% IACS voor staal. AC (60Hz) weerstand omvat huidige afhankelijk hysteresis verlies factor voor 1 en 3 layer constructies.
Huidige ratings zijn gebaseerd op 75OC geleider temperatuur, 25OC omgevingstemperatuur, 2ft/s wind, 96/watt/sq. Ft zon, 0.5 coëfficiënten van emissiviteit en absorptie.
Abc kabel |
|
Abc kabel
5. verpakking & verzending
Verpakking Detail: export houten drum pack kale acsr dirigent, houten ijzer drum en andere export standaard pakket
Levering Detail: 10 dagen en ook afhankelijk van de hoeveelheid
Drum Handling Praktijken
DO'S
|
|
DONT'S
|
Abc kabel
6. onze Voordelen:
ACSR blote geleider monster: wij bieden de steekproef gratis.
- Uitstekende elektrische en mechanische eigenschappen.
- Goede geleidbaarheid, Weerstand chemische corrosie en warmte-veroudering, milieu stress.
- Unit volume licht, Eenvoudig in structuur.
- Handig te gebruiken, vooral voor leggen over rivieren en valleien waar speciale geografische terrein bestaan.
Wij zijn de top van tien productie in china vasteland. Wij geven u een perfecte shopping ervaring. Als u bezoek aan onze fabriek, zullen wij aan u op de luchthaven of trein station.
Ook kunnen wij andere service
Custom Merchandise: kunnen we kabel als uw behoefte onder de kleur, grootte en zo op. we bieden ook OEM.
Complete Cursus Tracking: kunnen wij u de service van de business beginnen om je de kabel en gebruik het.
7. Company informatie
Zhengzhou hongda kabel Co, Ltd.
Opgericht Jaar: 1999
Kapitaal van RMB: 5,000,000
Fabriek Gebied: 300, 000m2
Belangrijkste producten: ABC kabel Areial bundel kabel, XLPE geïsoleerde stroomkabel, PVC geïsoleerde stroomkabel, elektrische draad, kale aluminium dirigent (AAC AAAC ACSR) en dus op
Belangrijkste export county: USA, Filippijnen, Maleisië, Indonesië, Venezuela, Colombia, Mexico, Dominica, india, Zuid-afrika, Zambia, Kenia enzovoort.
Abc kabel
Gerelateerde Producten:
ABC kabel overhead Antenne Bundel Kabel
Brandwerendheid kabel
Ondergrondse kabel met pvc isolatie
450/750 V BV elektrische draad
ACSR blote geleider overhead power kabel
We hopen op een vriendelijke relaties met u, zullen we proberen ons best om u tevredenheid.
Een nodig contact me als volgt:
Abc kabel
- Next: flame retardant zr-bvr building used cable / pvc insulated copper conductor electrical wire
- Previous: aac aluminum bare conductor hornet 19/3.25mm aac conductor bare stranded transmission line
Contact us
zoeken
You May Like
-
XLPE ABC Kabel Transmissie Elektrische Kabels Aluminium Geleider
-
0.6/1kv bs standaard 2/3/4/5 aders twist dirigent xlpe isolatie antenne bundel kabel abc kabel
-
Antenne bundel kabel Overhead lijn elektrische voedingskabel 3x70mm2 + 54.6mm2 + 16mm2 ABC kabel
-
Abc kabel antenne gebundeld kabel overhead kabel 3x25 mm2+54.6 mm2+16 mm2
-
Hoogspanningsleiding Elektrische Voedingskabel Aac/Aaac/Acsr/Abc Kabel