Huatong Type 10AWG Koperdraad Mtw-Nylon Jas-600 Volt
Haven: | Tianjin Port, China |
Betalingsvoorwaarden: | L/C,T/T,Western Union |
Leveringscapaciteit: | 1000000 Meter/meter per Month |
plaats van herkomst: | Hebei china |
naam van het merk: | REN DA |
modelnummer: | MTW |
type: | Geïsoleerd |
toepassing: | Machine-Tool Draden en Kabels |
leidingmateriaal: | Koper |
dirigent type: | Stranded |
isolatiemateriaal: | PVC |
Certificering: | UL Certificaat |
Nominale Spanning: | 600 V |
Isolatie: | PVC Isolatie Kabel |
Temperatuur: | 90 °C |
Vlam Compliances: | UL VW-1 |
Industrie Goedkeuringen: | UL Standaard 1063 |
Jas: | Nylon |
Details levering: | Binnen 15 dagen na ontvangst van uw storting |
Details verpakking: | Zachte Pakket |
HUATONG TYPE 10AWG Copper Wire MTW – Nylon Jacket – 600 Volts
PVC/Nylon Cable, Copper Conductors, 600 Volts, 90°C dry rated.
Construction
Conductor:
THHN: stranded, uncoated copper conductors per ASTM-B3, ASTM-B787
and ASTM-B8
• MTW: bare, annealed copper per ASTM-B3, -B8 and -B787
Insulation:
Color coded polyvinyl chloride (PVC), heat, moisture and flame retardant compound per UL 83 and UL 1063.
Covering:
A tough abrasion resistant polyamide (Nylon) covering.
Specifications
THHN / THWN-2 or MTW meets or exceeds all applicable ASTM specifications
UL 83: Thermoplastic-Insulated Wires and Cables
UL 1063: Machine-Tool Wires and Cables (stranded cables only)
NEMA WC70 / ICEA S-95-658: Power Cables Rated 2000V or Less for the Distribution of Electrical Energy
Federal Specification A-A-59544 and requirements of the NEC
CSA C22.2 No. 75-03 Thermoplastic Insulated Wires and Cables
Ratings
VW-1 rated 14 AWG – 1 AWG
1/0 AWG and larger is rated for CT (cable tray) use.
6 AWG and larger is rated for sunlight resistance in all colors. All sizes are rated "gasoline and oil resistant II."
Parameters:
We are one of China top rank cable&wire manufacturer.Our products meet standards of GB, IEC DIN ASTM, JIS, NF, AS/NZS CSA GOST and so on. We also have obtained ISO9001,ISO14001,OHSAS18001, UL,CE,
KEMA, TUV, SABS,PBS,Bureau Veritas, Lloyd,GL,NK,KR certifications.
We have obtained UL certifications for TC cable, DLO cable,RHH/RHW/RHW-2,XHHW/XHHW-2/SIS, THHN,SER/SEU/USE, MV-90/MV-105,MC cable,AC cable,TECK 90,SOOW,Welding cable,Mining cable,type DG,PV cable,Shipboard cable and so on.
CNAS accredited national level laboratory.
1.25 years production experience and 16 years export experience .
2.Products certification :UL,CE,BV,TUV,KEMA,PSB,SABS,ABS,NK,LR,KR,GL etc
3. OEM service available based on official & legal authorization.
4.Strict quality control system.
5.Rapid delivery and feedback Faster lead time than our competitors.
6.Excellent quality with reasonable price.
7.Strong technical support (technical data, drawing, etc.)
8.Professional teamwork service for you actively.
9.Stock available, Free sample is available.
(1).When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price,please call us or tell us in your e-mail so that we will regard your inquiry priority.
(2).How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
(3).How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express account or prepay us if you do not have an account.
(4).What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order.The best record we keep is delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.
- Next: 0.6/1KV 70mm2 95mm2 copper conductor XLPE armored power cable
- Previous: Wet or dry locations soft copper conductor PVC sheath SE-U cable